THE RANGE FOR GARDENING AND LANDSCAPING

STRONG, SOLID FIBRE REINFORCED CONCRETE CHANNEL SYSTEM

FOR USE IN PEDESTRIAN AND DOMESTIC AREAS

  • Channels
  • Gratings
  • FASERFIX STANDARD E 100 - Accessories
  • I'm a new text node.
  • I'm a new text node.
  • I'm a new text node.
  • I'm a new text node.
  • I'm a new text node.
  • I'm a new text node.

Collecting tender proposals.

80008200
Sample imageType 01
Sample image
Type 01

FASERFIX STANDARD 100 E

STRONG, SOLID FIBRE REINFORCED CONCRETE CHANNEL SYSTEM

FOR USE IN PEDESTRIAN AND DOMESTIC AREAS
    No selection
    FASERFIX-Standard 100 E-KR-Steg Bild

    Slotted gratings

    Applies to classes:

    • Walkable
    • Sustains car traffic
    FASERFIX-Standard 100 E-KMR 30/10 Bild

    Mesh grating

    Applies to classes:

    • B 125
    • B 125
    FASERFIX-Standard 100 E-GUGI schw., Kl. C Bild

    GuGis

    Applies to classes:

    • C 250
    • C 250
    FASERFIX STANDARD E 100 - Channels
    Length mm Width mm Height mm Drainage cross-sect. cm² Weight kg Item No.
    Type 01

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 140 89 29,0 6200
    Type 01L with hole*

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 140 89 30,0 6300
    Type 010

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 194 143 38,0 6242
    Type 010L with hole*

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 194 143 39,4 6342
    Type 0105

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-STANDARD E 100-Rinne, Typ 0105 Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-STANDARD E 100-Rinne, Typ 0105 Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    500 160 140 89 15,0 6249
    * Distance from middle of the hole (DN100) to the end of the channel: 100 mm.


    FASERFIX STANDARD E 100 - Channels with built-in fall 0,6 %
    Length mm Width mm Height mm Drainage cross-sect. cm² Weight kg Item No.
    Type 1

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 140 - 146 89 32,0 6201
    Type 2

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 146 - 152 95 32,0 6202
    Type 3

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 152 - 158 101 33,0 6203
    Type 4

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 158 - 164 107 34,0 6204
    Type 5

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 164 - 170 113 35,0 6205
    Type 6

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 170 - 176 119 35,0 6206
    Type 7

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 176 - 182 125 35,0 6207
    Type 8

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 182 - 188 131 35,0 6208
    Type 9

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 188 - 194 137 35,0 6209
    Type 10

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Rinne Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Rinne Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 160 194 - 200 143 38,0 6210
    FASERFIX STANDARD E 100 - Gratings, car traffic
    Length mm Width mm Height mm Intake cross-sect. cm²/m Weight kg Item No.
    Slotted grating SW 9, galvanised

    Dokumente:

    • Test certificate
      Prüfungsbericht_KR-Steg_KlA15_FASERFIX/RECYFIX
    • Product image (inventor image)
      FASERFIX-Standard 100 E-KR-Steg Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 158 21 280 2,3 6270
    Slotted grating SW 9, garvanised

    Dokumente:

    • Test certificate
      Prüfungsbericht_KR-Steg_KlA15_FASERFIX/RECYFIX
    • Product image (inventor image)
      FASERFIX-Standard 100 E-KR-Steg Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    500 158 21 280 1,1 6271
    FASERFIX STANDARD E gratings heighten the channel upper edge 4 mm.


    FASERFIX STANDARD E 100 - Gratings, class B 125
    Length mm Width mm Height mm Intake cross-sect. cm²/m Weight kg Item No.
    Mesh grating MW 30/10, galvanised

    Dokumente:

    • Product image (inventor image)
      FASERFIX-Standard 100 E-KMR 30/10 Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    • Product image (inventor image)
      FASERFIX-Standard 100 E-KMR 30/10 Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    1000 158 20 650 3,4 6280
    Mesh grating MW 30/10, galvanised

    Dokumente:

    • Product image (inventor image)
      FASERFIX-Standard 100 E-KMR 30/10 Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    • Product image (inventor image)
      FASERFIX-Standard 100 E-KMR 30/10 Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    500 158 20 650 1,8 6281
    FASERFIX STANDARD E gratings heighten the channel upper edge 4 mm.


    FASERFIX STANDARD E 100 - Gratings, class C 250
    Length mm Width mm Height mm Intake cross-sect. cm²/m Weight kg Item No.
    GUGI-Ductile iron mesh grating MW 20/30, black

    Dokumente:

    • Product image (inventor image)
      FASERFIX-Standard 100 E-GUGI schw., Kl. C Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    500 158 14 444 3,2 6267
    GUGI-Ductile iron mesh grating, KTL (minimum order quantity: 400 pieces, delivery time approx. 4 weeks)

    Dokumente:

    • Product image (inventor image)
      FASERFIX-Standard 100 E-GUGI schw., Kl. C Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    500 158 14 444 3,4 6467
    FASERFIX STANDARD E gratings heighten the channel upper edge 4 mm.
    We recommend to fix the GUGI-Ductile iron mesh gratings with locking handle art.-no. 5095 roadworthy.


    FASERFIX STANDARD E 100 - Accessories
    Length mm Width mm Height mm Weight kg Item No.
    Trash box with plastic bucket

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Einlaufkasten Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Einlaufkasten Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    500 160 480 41,4 6253
    Trash box with galvanised bucket

    Dokumente:

    • Sectional view (JPG)
      FASERFIX-Standard 100 E-Einlaufkasten Schnittdarstellung
    • Product image (inventor image)
      FASERFIX-Standard 100 E-Einlaufkasten Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    500 160 480 42,4 6255
    Foul air trap DN 100 with hole

    Dokumente:

    • Product image (inventor image)
      FASERFIX-Standard-Geruchverschluss senkr. Bild
    • Test certificate
      Prüfungsbericht_Faserfix_Standard_100_KlC
    • Test certificate
      Prüfungsbericht_Wasseraufnahme_FASERFIX_Standard
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Asphalt Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. A 15 in Asphalt Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. A 15 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Beton Einbaubeispiel
    - - - 0,2 964
    UPVC-outlet DN 100

    Dokumente:

    • Product image (inventor image)
      Kunststoff-Stutzen DN 100 Bild
    • CE-Konformitätserklärungen
      FASERFIX-SUPER KS 100 Konformität
    • CE-Konformitätserklärungen
      FASERFIX-SUPER KS 100 Konformität engl.
    • Installation example (drawing)
      FASERFIX SUPER KS Rinne flach Kl. C 250 in Zementestrich Einbaubeispiel
    • Installation example (drawing)
      FASERFIX SUPER KS Rinne flach Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX SUPER KS Rinne flach Kl. C 250 in Zementestrich/Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX SUPER KS Rinne flach Kl. C 250 in Pflaster Einbaubeispiel
    - - - 0,2 903
    End cap closed, galvanised, Type 01

    Dokumente:

    • Product image (inventor image)
      FASERFIX-Standard-Stirnwand geschl. Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    - 160 140 0,3 6290
    End cap closed, galvanised, Type 010

    Dokumente:

    • Product image (inventor image)
      FASERFIX-Standard-Stirnwand geschl. Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    - 160 194 0,4 6291
    End cap with horizontal PVC-outlet DN 100, galvanised, Type 010

    Dokumente:

    • Product image (inventor image)
      FASERFIX-SUPER, Typ 010-Stirnwand m. Kst.-Ausl. Bild
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-STANDARD E 100 Konformität
    • Test certificate
      Prüfungsbericht FASERFIX STANDARD E 100 Kl. C
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Beton Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX STANDARD E 100/150 Rinne Kl. C 250 in Asphalt Einbaubeispiel
    - 160 194 0,5 6297
    Cutting to length of NW 100

    Dokumente:

    • Product image (inventor image)
      Werkseitiges Schneiden von NW 100 Bild
    • Test certificate
      Prüfungsbericht_Faserfix_Standard_100_KlC
    • Test certificate
      Prüfungsbericht_Wasseraufnahme_FASERFIX_Standard
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Asphalt Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. A 15 in Asphalt Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. A 15 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Beton Einbaubeispiel
    - - - - 994
    Mitre cuts NW 100 (price per cut, two cuts necessary)

    Dokumente:

    • Product image (inventor image)
      FASERFIX-Standard-Sonderservice Gehrungsschnitt f. Eckverbindung Bild
    • Test certificate
      Prüfungsbericht_Faserfix_Standard_100_KlC
    • Test certificate
      Prüfungsbericht_Wasseraufnahme_FASERFIX_Standard
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Asphalt Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. A 15 in Asphalt Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. A 15 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Beton Einbaubeispiel
    - - - - 999
    Drilling of connectiong holes DN 100

    Dokumente:

    • Product image (inventor image)
      Werks. Bohren von Anschlussöffnung Bild
    • Test certificate
      Prüfungsbericht_Faserfix_Standard_100_KlC
    • Test certificate
      Prüfungsbericht_Wasseraufnahme_FASERFIX_Standard
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Asphalt Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. A 15 in Asphalt Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. A 15 in Pflaster Einbaubeispiel
    • Installation example (drawing)
      FASERFIX-STANDARD 100-Rinne Kl. C 250 in Beton Einbaubeispiel
    - - - - 977
    Inserting of PVC union connectors DN 100 *

    Dokumente:

    • Product image (inventor image)
      Werkseitiges Einsetzen von Stutzen DN 100 NW 100 (inkl. Bohrung) Bild
    • CE-Konformitätserklärungen
      FASERFIX-SUPER 300 Konformität engl.
    • CE-Konformitätserklärungen
      FASERFIX-SUPER 300 Konformität
    - - - - 982
    • HAURATON
      • LANDSCAPING
        • FASERFIX®STANDARD
          • FASERFIX®STANDARD E 100
    • Top of page
    • Print version
    • RECYFIX®PRO
    • RECYFIX®PLUS
    • RECYFIX®STANDARD
    • SLOTTED CHANNEL
    • FASERFIX®STANDARD
      • FASERFIX®STANDARD E 100
    • RECYFIX®POINT
    • FASERFIX®POINT
    • DACHFIX®
    • RECYFIX®GREEN
    • LINEFIX®
    • TOP
    • CIVILS
      • FASERFIX®SUPER KS
      • FASERFIX®SUPER
      • RECYFIX®SUPER KS
      • RECYFIX®PLUS
      • FASERFIX®BIG BL
      • FASERFIX®BIG SL
      • RECYFIX®HICAP®F
      • RECYFIX®HICAP®G
      • FASERFIX®POINT
    • LANDSCAPING
      • RECYFIX®PRO
      • RECYFIX®PLUS
      • RECYFIX®STANDARD
      • SLOTTED CHANNEL
      • FASERFIX®STANDARD
      • RECYFIX®POINT
      • FASERFIX®POINT
      • DACHFIX®
      • RECYFIX®GREEN
      • LINEFIX®
      • TOP
    • AQUA
      • DRAINFIX®BLOC
      • DRAINFIX®TWIN
      • AQUAFIX®
    • SPORT
      • SPORTFIX®Channels
      • SPORTFIX®Soft kerbs
      • SPORTFIX®sand traps
      • SPORTFIX®water jump kit
      • SPORTFIX®turf edging plate
      • SPORTFIX®dish channels
      • SPORTFIX®distribution shaft
    • References
      • Data base of references
      • Interesting projects
    • Service
      • Individual catalogue
      • Product videos
      • Service package
      • Downloads
      • Installation advice
    • Home
    • About us
      • HYGRADE WATER AUSTRALIA
      • Hauraton in Rastatt and Ötigheim
      • Hauraton International
      • Hauraton History
      • Hauraton certificates
      • HAURATON INNOVATIONS
    • News
      • Design Build 2009 in Sydney
      • Trade fairs
      • Trade fairs, Archive
    • Contact
      • E-Mail
      • Postal / Phone
      • Visit us
    • Imprint
    Hauraton Drainage
    Hauraton Drainage
    advanced search
    Australia
    • Deutsch
    • English
    • France
    • Australia
    • Brasil
    • Bulgaria
    • Croatia
    • Czech Republic
    • Hungary
    • Ireland
    • Italia
    • Lithuania
    • Netherlands
    • New Zealand
    • Poland
    • Portugal
    • Romania
    • Russia
    • Serbia
    • Spain
    • Slovakia
    • Slovenia
    • Turkey
    • Ukrajina
    • United Kingdom